On This Page On This Page Purchase with Confidence Make an informed autoclave purchasing decision by asking these key questions before you buy. Download the eBook Canopy Hood Designs: An Important Consideration for Your Lab Written by: Scott Mechler BS Mechanical Engineering, Mechanical Engineer You have a lot of choices when it comes to ventilation solutions for your autoclave and some are better than others. Canopy hoods are an optimal solution for handling odors, steam moisture and low-levels of chemical vapors. The following are guidelines from the National Institute for Health for the design of autoclave door canopy hoods. The canopy should extend 1 foot wider (6 inches on each side) than the open autoclave door and the front end of the hood should extend so that it is at least 6 inches further out from the fully open autoclave door. The height of the hood above the autoclave door should be from 3 inches to a maximum of 3 foot above, with the shortest distance possible to prevent employees from hitting their heads on the hood and allow access to controls. The total flow rate for the canopy hood is calculated using the following equation (Industrial Ventilation Manual 25th Edition; please see the note below): Qt = 6.2 x L x b1.33Δt0.42 where: Qt = total hood air flow, cfm L = length of the canopy hood, ft b = width of the canopy hood, ft Δt = difference between temperature of the hot source and the ambient, F. Note: This equation is applicable if the distance between the hood and the hot waste does not exceed the length/width of the waste or 3 ft, whichever is smaller. Please note that this equation applies to hot processes but does not account for the effects of high pressure. Since a canopy hood is a receiving hood not a capture hood, the airflow rate to the canopy should be at least 10% higher than the rate of steam and gas generated from the autoclave. Sample calculation: if an autoclave operated at 250F has an opening of 3 ft length and 2 ft width (room air temperature is 70F), the required total hood air flow is Qt = 6.2 x (3+1) x (2+1)1.33 x (250 – 70)0.42 = 950(cfm) * *Note: 1 foot added to the length and width of the canopy hood per the design guidelines listed above Consolidated does not provide specifications for exhaust hoods or canopies. We leave the particulars of the lab ventilation system to the HVAC engineers. We do however strongly urge all of our clients to invest in such equipment. While there is the concern that a lab ventilation system can create exorbitant costs related to energy use and loss of conditioned air, engineers at Consolidated recommend the following simple energy saving feature: Use Dry contacts to tie the canopy hood into the autoclave control system such that the ventilation only occurs when needed (i.e. when the autoclave door is opened after a cycle). In addition to dry contacts, some hood designs are more energy conscious by being demand-based, which only ramp up when particles (steam, smoke) or heat is detected. Contact us today to learn more about our ventilation recommendations for autoclaves or to talk to one of our service technicians about other solutions. 17 Questions to Ask Before Buying Your Next Autoclave With so many models, sizes, options and components to choose from, how can you ever really know exactly what you need to make the most out of your investment? These questions will help you to make informed decisions by outlining what is most important to consider and know about owning an autoclave. LinkedIn (Optional)This field is for validation purposes and should be left unchanged.First Name*Last Name*Company/Organization*Email* Job Title*Select OneArchitectGeneral ContractorLab ManagerFacilities ManagerService TechnicianScientistSterile Processing TechnicianDistributorOtherDescribe "Other"*Country*United StatesAnguillaAntigua and BarbudaArubaBahamasBarbadosBermudaCanadaCosta RicaDominican RepublicHondurasJamaicaMartiniqueMexicoPuerto RicoSaint Kitts and NevisSaint LuciaTrinidad and TobagoTurks and CaicosOtherState*Select OneAlabamaAlaskaArizonaArkansasCaliforniaColoradoConnecticutDelawareFloridaGeorgiaHawaiiIdahoIllinoisIndianaIowaKansasKentuckyLouisianaMaineMarylandMassachusettsMichiganMinnesotaMississippiMissouriMontanaNebraskaNevadaNew HampshireNew JerseyNew MexicoNew YorkNorth CarolinaNorth DakotaOhioOklahomaOregonPennsylvaniaRhode IslandSouth CarolinaSouth DakotaTennesseeTexasUtahVermontVirginiaWashingtonWest VirginiaWisconsinWyomingAre You Looking to Purchase an Autoclave?*Select OneYes, ImmediatelyYes, within 6 monthsYes, later than 6 monthsNo, just researchingPhone*Are you in a medical/healthcare (patient use) or life science (laboratory) setting?*Select OneMedical/HealthcareLife ScienceWhat type of healthcare facility do you work in?*Select OneHospitalAmbulatory Surgery CenterVeterinary/Vet HospitalDentalFamily PracticeOther Yes, I'd like to receive occasional tips on sterilization best practices. Δ Tweet Like Share
Canopy Hood Designs: An Important Consideration for Your Lab Written by: Scott Mechler BS Mechanical Engineering, Mechanical Engineer You have a lot of choices when it comes to ventilation solutions for your autoclave and some are better than others. Canopy hoods are an optimal solution for handling odors, steam moisture and low-levels of chemical vapors. The following are guidelines from the National Institute for Health for the design of autoclave door canopy hoods. The canopy should extend 1 foot wider (6 inches on each side) than the open autoclave door and the front end of the hood should extend so that it is at least 6 inches further out from the fully open autoclave door. The height of the hood above the autoclave door should be from 3 inches to a maximum of 3 foot above, with the shortest distance possible to prevent employees from hitting their heads on the hood and allow access to controls. The total flow rate for the canopy hood is calculated using the following equation (Industrial Ventilation Manual 25th Edition; please see the note below): Qt = 6.2 x L x b1.33Δt0.42 where: Qt = total hood air flow, cfm L = length of the canopy hood, ft b = width of the canopy hood, ft Δt = difference between temperature of the hot source and the ambient, F. Note: This equation is applicable if the distance between the hood and the hot waste does not exceed the length/width of the waste or 3 ft, whichever is smaller. Please note that this equation applies to hot processes but does not account for the effects of high pressure. Since a canopy hood is a receiving hood not a capture hood, the airflow rate to the canopy should be at least 10% higher than the rate of steam and gas generated from the autoclave. Sample calculation: if an autoclave operated at 250F has an opening of 3 ft length and 2 ft width (room air temperature is 70F), the required total hood air flow is Qt = 6.2 x (3+1) x (2+1)1.33 x (250 – 70)0.42 = 950(cfm) * *Note: 1 foot added to the length and width of the canopy hood per the design guidelines listed above Consolidated does not provide specifications for exhaust hoods or canopies. We leave the particulars of the lab ventilation system to the HVAC engineers. We do however strongly urge all of our clients to invest in such equipment. While there is the concern that a lab ventilation system can create exorbitant costs related to energy use and loss of conditioned air, engineers at Consolidated recommend the following simple energy saving feature: Use Dry contacts to tie the canopy hood into the autoclave control system such that the ventilation only occurs when needed (i.e. when the autoclave door is opened after a cycle). In addition to dry contacts, some hood designs are more energy conscious by being demand-based, which only ramp up when particles (steam, smoke) or heat is detected. Contact us today to learn more about our ventilation recommendations for autoclaves or to talk to one of our service technicians about other solutions. 17 Questions to Ask Before Buying Your Next Autoclave With so many models, sizes, options and components to choose from, how can you ever really know exactly what you need to make the most out of your investment? These questions will help you to make informed decisions by outlining what is most important to consider and know about owning an autoclave. LinkedIn (Optional)This field is for validation purposes and should be left unchanged.First Name*Last Name*Company/Organization*Email* Job Title*Select OneArchitectGeneral ContractorLab ManagerFacilities ManagerService TechnicianScientistSterile Processing TechnicianDistributorOtherDescribe "Other"*Country*United StatesAnguillaAntigua and BarbudaArubaBahamasBarbadosBermudaCanadaCosta RicaDominican RepublicHondurasJamaicaMartiniqueMexicoPuerto RicoSaint Kitts and NevisSaint LuciaTrinidad and TobagoTurks and CaicosOtherState*Select OneAlabamaAlaskaArizonaArkansasCaliforniaColoradoConnecticutDelawareFloridaGeorgiaHawaiiIdahoIllinoisIndianaIowaKansasKentuckyLouisianaMaineMarylandMassachusettsMichiganMinnesotaMississippiMissouriMontanaNebraskaNevadaNew HampshireNew JerseyNew MexicoNew YorkNorth CarolinaNorth DakotaOhioOklahomaOregonPennsylvaniaRhode IslandSouth CarolinaSouth DakotaTennesseeTexasUtahVermontVirginiaWashingtonWest VirginiaWisconsinWyomingAre You Looking to Purchase an Autoclave?*Select OneYes, ImmediatelyYes, within 6 monthsYes, later than 6 monthsNo, just researchingPhone*Are you in a medical/healthcare (patient use) or life science (laboratory) setting?*Select OneMedical/HealthcareLife ScienceWhat type of healthcare facility do you work in?*Select OneHospitalAmbulatory Surgery CenterVeterinary/Vet HospitalDentalFamily PracticeOther Yes, I'd like to receive occasional tips on sterilization best practices. Δ Tweet Like Share
12.10.25 Introducing SterilSteam Sampler, The Steam Condensate Sampler for AAMI ST108 Compliance → Released in 2023, AAMI/ANSI ST108 establishes water quality requirements for water used in the cleaning, rinsing, disinfection, and sterilization of reusable medical devices. In addition to these requirements, ST108 mandates quarterly testing of steam condensate quality to ensure incoming steam does not stain instruments or pose a risk to patient safety. To help healthcare facilities […]
11.6.25 AAMI ST108 & Critical Water for Autoclaves: What ASCs Need to Know → A major step forward in patient safety, ANSI/AAMI ST108 establishes new minimum water quality requirements for water used in the cleaning, rinsing, disinfection, and sterilization of reusable medical devices. Despite providing guidance on water quality management for sterile processing, ST108 has also created confusion, especially regarding test protocols, water treatment, and critical water requirements. In […]
10.20.25 What Is an Autoclave Machine Really Used for? [Applications, Costs & More] → Autoclave machines are mission-critical equipment in a variety of industries, from healthcare to biotech, ensuring equipment and materials are sterilized and safe for use. Whether you’re considering purchasing an autoclave for a new facility, replacing a broken one, or expanding your current sterilization capacity, understanding the ins and outs of autoclave technology is key to […]